Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 18(12): e0294891, 2023.
Article in English | MEDLINE | ID: mdl-38085718

ABSTRACT

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an X-linked genetic disorder characterized by reduced G6PD enzyme levels in the blood. This condition is common in populations exposed to malaria; an acute febrile disease caused by Plasmodium parasites. G6PD-deficient individuals may suffer from acute hemolysis following the prescription of Primaquine, an antimalarial treatment. The population at risk for such a condition includes the Senoi group of Orang Asli, a remote indigenous community in Malaysia. This study aimed to elucidate the G6PD molecular heterogeneity in this subethnic group which is important for malaria elimination. A total of 662 blood samples (369 males and 293 females) from the Senoi subethnic group were screened for G6PD deficiency using a quantitative G6PD assay, OSMMR2000-D kit with Hb normalization. After excluding the family members, the overall prevalence of G6PD deficiency in the studied population was 15.2% (95% CI: 11-19%; 56 of 369), with males (30 of 172; 17.4%) outnumbering females (26 of 197; 13.2%). The adjusted male median (AMM), defined as 100% G6PD activity, was 11.8 IU/gHb. A total of 36 participants (9.6%; 26 male and 10 female) were deficient (<30% of AMM) and 20 participants (5.4%; 4 male and 16 female) were G6PD-intermediate (30-70% of AMM). A total of 87 samples were genotyped, of which 18 showed no mutation. Seven mutations were found among 69 genotyped samples; IVS11 T93C (47.1%; n = 41), rs1050757 (3'UTR +357A>G)(39.1%; n = 34), G6PD Viangchan (c.871G>A)(25.3%; n = 22), G6PD Union (c.1360C>T)(21.8%; n = 19), c.1311C>T(20.7%; n = 18), G6PD Kaiping (c.1388G>A)(8.0%; n = 7), and G6PD Coimbra (c.592C>T)(2.3%; n = 2). Our analysis revealed 27 hemizygote males, 18 heterozygote females, 7 homozygote females, and 2 compound heterozygote females. This study confirms the high prevalence of G6PD deficiency among the Senoi Malaysian Orang Asli, with a significant degree of molecular heterogeneity. More emphasis should be placed on screening for G6PD status and proper and safe use of Primaquine in the elimination of malaria among this indigenous population.


Subject(s)
Glucosephosphate Dehydrogenase Deficiency , Malaria , Female , Humans , Male , Glucosephosphate Dehydrogenase/genetics , Glucosephosphate Dehydrogenase/analysis , Glucosephosphate Dehydrogenase Deficiency/epidemiology , Glucosephosphate Dehydrogenase Deficiency/genetics , Glucosephosphate Dehydrogenase Deficiency/diagnosis , Malaria/epidemiology , Malaysia/epidemiology , Prevalence , Primaquine/adverse effects
2.
Front Public Health ; 11: 1199234, 2023.
Article in English | MEDLINE | ID: mdl-38045974

ABSTRACT

Introduction: Unmanned aerial vehicles (UAVs) are used for commercial, medical, public safety, and scientific research purposes in various countries. Methods: This study aimed to explore the acceptance of medical delivery drones among medical practitioners as well as the public community in Malaysia using a knowledge, attitude, and perception (KAP) model and statistical analysis to decrease uncertainty. Bivariate and multivariate analyses of the results were performed in SPSS. Results: A total of 639 respondents took part in the survey, of which 557 complete responses were finally analyzed. The results showed that the overall acceptance rate for medical delivery drones was positive. The acceptance rate was significantly correlated with knowledge, attitude, and perception scores but not with sociodemographic factors. Discussion: Raising awareness and educating the medical as well as public communities regarding the potential role and benefits of drones are therefore important in garnering support for drone usage for medical purposes.


Subject(s)
Health Knowledge, Attitudes, Practice , Unmanned Aerial Devices , Perception , Technology , Malaysia
3.
Front Genet ; 14: 1098828, 2023.
Article in English | MEDLINE | ID: mdl-37388931

ABSTRACT

Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is an X-linked hereditary disorder and a global public health concern that is most prevalent in malaria-endemic regions including Asia, Africa, and the Mediterranean. G6PD-deficient individuals are at high risk of developing acute hemolytic anemia following treatment with antimalarial drugs including Primaquine and Tafenoquine. However, the currently available tests for G6PD screening are complex and often have been misclassifying cases, particularly for females with intermediate G6PD activity. The latest innovation of quantitative point-of-care (POC) tests for G6PD deficiency provides an opportunity to improve population screening and prevent hemolytic disorders when treating malaria. Aim(s): To assess the evidence on the type and performance of quantitative point-of-care (POC) tests for effective G6PD screening and hence, radical elimination of Plasmodium malaria infections. Methods: Relevant studies published in English language confined from two databases, Scopus and ScienceDirect were searched from November 2016 onwards. The search was conducted using keywords including "glucosephosphate dehydrogenase" or "G6PD", "point-of-care", "screening" or "prevalence", "biosensor" and "quantitative". The review was reported following the PRISMA guidelines. Results: Initial search results yielded 120 publications. After thorough screening and examination, a total of 7 studies met the inclusion criteria, and data were extracted in this review. Two types of quantitative POC tests were evaluated, namely, the CareStartTM Biosensor kit and the STANDARD G6PD kit. Both tests showed promising performance with high sensitivity and specificity ranging mostly from 72% to 100% and 92%-100%, respectively. The positive and negative predictive values (PPV and NPV) ranged from 35% to 72% and 89%-100%, with accuracy ranging from 86% to 98%. Conclusion: In areas with a high prevalence of G6PD deficiency that overlap with malaria endemicity, availability and validation of the diagnostic performance of quantitative POC tests are of absolute importance. Carestart™ biosensor and STANDARD G6PD kits showed high reliability and performed well in comparison to the spectrophotometric reference standard.

4.
PLoS One ; 17(9): e0269866, 2022.
Article in English | MEDLINE | ID: mdl-36070297

ABSTRACT

The disruptive potentials of drones are rapidly growing including for the delivery of blood samples in healthcare. Maintenance of the quality of blood samples is important to ascertain that the drone is a safe mode of transportation, particularly during emergencies and in critical cases. The influence of the drone carriage material on blood samples transportation was investigated in this study. Two phases of drone simulation flights were conducted in Cyberjaya, Malaysia. In Phase 1, the effect of drone carriage material on the internal storage temperature during blood samples transportation was determined. Three types of carriage materials were compared: aluminium, expanded polystyrene (EPS) foam, and polypropylene (PP) plastic. In Phase 2, the quality of drone-transported blood samples was assessed, using the best material from Phase 1 as the drone carriage material. Biochemical and hematological analyses of 60 blood samples were conducted using five parameters. In Phase 1, EPS foam was found to be the best material to maintain a stable and favorable internal storage temperature at mean kinetic temperature ±SD of 4.70 ±1.14°C. Much higher and unfavorable mean kinetic temperatures were recorded for aluminium (11.46 ±0.35°C) and plastic (14.17 ±0.05°C). In Phase 2, laboratory tests show that the quality of blood samples was well maintained, and the mean biochemical and hematological parameters of drone-transported blood samples showed no significant alteration compared to ground controls. Drone carriage material is an important determinant of the quality of blood samples transported by drone, particularly in hot equatorial climates as in Malaysia. The blood storage temperature was best maintained using EPS foam, as evidenced by the favorable average temperature and preservation of hematological and biochemical parameters of the blood samples.


Subject(s)
Aluminum , Unmanned Aerial Devices , Climate , Plastics , Temperature
5.
Medicine (Baltimore) ; 99(36): e21967, 2020 Sep 04.
Article in English | MEDLINE | ID: mdl-32899033

ABSTRACT

INTRODUCTION: Medical products transportation has become an important research topic requiring multidisciplinary collaboration among experts in medicine, engineering, and health economics. Current modes of transportation are unable to overcome the limited settings in maternal healthcare, particularly during the event of obstetric emergencies. The drone is a promising medical product aerial transportation (MedART) that holds an enormous potential for delivery of medical supplies in the healthcare system. We conducted a systematic review to examine scientific evidence of positive impact of drone transportation on maternal health. METHODS: The following electronic databases were searched from inception to July 2019: ScienceDirect, PubMed, and EMBASE. The report was made in accordance with the principles of PRISMA guidelines. The search terms used were related to drones including unmanned aerial vehicle (UAV) and unmanned aerial system (UAS), and related to obstetric/maternal including obstetric emergencies and postpartum hemorrhage. Studies were selected if the intervention used were drones, and if any direct or indirect maternal health indicators were reported. Meta-analysis was not done throughout the study in view of the anticipated heterogeneity of each study. RESULTS: Our initial search yielded a total of 244 relevant publications, from which 236 were carried forward for a title and abstract screening. After careful examination, only two were included for systematic synthesis. Among the reasons for exclusion were irrelevance to maternal health purpose, and irrelevance to drone applications in healthcare. An updated search yielded one additional study that was also included. Overall, two studies assessed drones for blood products delivery, and one study used drones to transport blood samples. CONCLUSION: A significant deficiency was found in the number of reported studies analyzing mode of medical products transportation and adaptation of drones in maternal healthcare. Future drone research framework should focus on maternal healthcare-specific drone applications in order to reap benefits in this area.


Subject(s)
Aircraft/instrumentation , Maternal Health Services/organization & administration , Remote Sensing Technology/instrumentation , Emergencies , Female , Humans , Maternal Health Services/trends , Pregnancy , Remote Sensing Technology/trends
SELECTION OF CITATIONS
SEARCH DETAIL
...